Absolute Encoder
|
OPTOCODE
|
CANopen Safety
 |
OPTOCODE Specifications - Optical Measurement Principle
- Resolution Per Revolution up to 16 Bit (65536 Steps)
- Up to 16384 (14 bit) Revolutions With Mechanical Gearing, No Battery Back Up
- Operating Temperature -30 to +70 °C
- Environmental Protection IP 65 Enclosure and up to IP 66 on Shaft Side
- Hollow Shaft or Solid Shaft Flanges
- Stainless Steel Available
- Simultaneous Operation of CANopen (DS301) and CANopen Safety (DS304) Protocol
CANopen Safety- Certified by TUV Rheinland, Number: 01/205/0701/10
- Safety Integrity Level (EN 62061): SIL CL 3
- PFDav (EN 62061): 27% according to SIL 3
- Performance Level (EN ISO 13849-1): PL e
- Safety Category (EN ISO 13849-1): Cat 4
- MTTFd (EN ISO 13849-1): 129 Years
- CANopen Safety Communication Profile acc. to DS 304
- Simultaneous Operation of CANopen Protocol acc. to DS301
- Transmission of "Safety Position Value", no Position Validation in PLC Necessary
- Fulfills Actual Machine Directive
- More Cost Efficient than Redundant Realization with 2 Standard Encoder And Coverage of Common Failure
- High Availability
- Redundant Logical und Physical Architecture
- Usage in Lift Platforms, Cranes, Mobile Machines
- Communication Profile According to DS 301
- Device Profile DS 406
- Programmable According to Class 2
Version with Connection Cap - Device Address and Baudrate Is Set Via BCD Rotary Switches
- LEDs for Status Indication
- Integrated T-Distributor
- Switchable Terminating Resistor
Version with Cables and Connectors- Device Address and Baudrate Is Set Via Software
|
|
|